Page 2

COMPONENT GUIDEIgnition and Flame RecognitionSequence Of EventsComponentInput Voltage CheckOutput Voltage CheckResistance and Various Tests (With test

Page 3 - FlowChart

COMPONENT GUIDEIgnition and Flame Recognition, ContinuedSequence Of EventsComponentInput Voltage CheckOutput Voltage CheckResistance and Various Tests

Page 4

COMPONENT GUIDEEnd of Cook CycleSequence Of EventsComponentInput Voltage CheckOutput Voltage CheckResistance and Various Tests (With test leads discon

Page 5

TROUBLESHOOTING – Quick ReferenceREADY TO COOK WAIT, BROILER PRE-HEATINGTEMPERATURE TOO HIGH,CALL FOR SERVICETEMPERATURE TOO LOWWAIT, UNTIL READY TO C

Page 6

Index Troubleshooting FlowChart Quick Index……………………………………………………………………….3 FlowChart……………………………………………………………………….4-8 Component Guide Power On Compo

Page 7

Display showing “Lo”Display flashing “tESt” and “Prod”SEntDisplay flashing “gAS” and…. toP SEnbbotDisplay showing “Hi”Display showing “Prob”Define the

Page 8

Does Controller Displaylight up?NOYESVerify 120 VAC present at receptacle.Upon turning on, does thelower burner ignite andstay on?Ensure 120 VAC at in

Page 9

Upon reaching 500F, dothe upper infrared burnersignite and stay lit?YESYESNONo Gas. Ensureincoming gas supply isavailable.Faulty igniter orinsufficien

Page 10 - COMPONENT GUIDE

Does the Broiler reachsetpoint temperature anddisplay RDY?NOYESTroubleshootingFlowChartYESConsult nextpageYESDisplay flashing“gAS” and….YESDisplay fla

Page 11

Does the Lower Burner cycleon and off to maintain idletemperature? (Typically 680 F)NOYESTroubleshootingFlowChartYESConsult nextpageYESSee Step 2Durin

Page 12

At the end of a cookcycle, does the conveyorbelt discharge properly?NOImproperly installed. Discharge chute is not properly inplace.Belt hanging up.