At the end of a cook
cycle, does the conveyor
belt discharge properly?
NO
Improperly installed. Discharge chute is not properly in
place.
Belt hanging up. Conveyor belt is catching on another
item, i.e. ash scraper, loader ramp, flame arrestor.
Loose drive chain. Deflection of chain should be
approximately 3/16".
YES
Faulty capacitor. Test conveyor motor capacitor for
fault.
Faulty relay. Ensure conveyor motor relay is closing.
Replace relay if conveyor motor running nonstop.
Faulty Controller. Ensure Controller is signaling to
energize the conveyor motor relay.
Loose motor sprocket. When tightening, ensure motor
sprocket is orientated the same way as the shaft
sprocket.
Faulty conveyor motor. Test conveyor motor for fault.
Troubleshooting
FlowChart
Broiler Working
Properly